RECEIVING INSTRUCTIONS
Inspect shipment immediately when
received to determine if any damage
has occurred to the unit during
shipment. After the unit has been
uncrated, check for any visible
damage to the unit. If any damage
is found, the consignee should sign
the bill of lading indicating such
damage and immediately fi le claim for
damage with the transportation
company.
INSTALLER’S RESPONSIBILITY
Installer Please Note: This equipment has been test fi red and
inspected. It has been shipped free from defects from our factory.
However, during shipment and installation, problems such as loose
wires, leaks or loose fasteners may occur. It is the installer’s
responsibility to inspect and correct any problems that may
be found.
IMPORTANT: Look in direction of unit air fl ow to determine
whether unit is right hand or left hand accessible.
Install, operate and maintain unit in accordance
with manufacturer’s instructions to avoid exposure to fuel
substances or substances from incomplete combustion which
can cause death or serious illness. The state of California has
determined that these substances may cause cancer, birth
defects, or other reproductive harm. Install and Service this
product to avoid exposure to airborne particles of glasswool
bers and/or ceramic fi bers known to the State of California to
cause cancer through inhalation.
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or death.
This appliance must be installed by a licensed contractor or
qualifi ed service personnel. Read these installation, operating
and maintenance instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY
The use or storage of
gasoline or other fl ammable
vapors or liquids in open
containers in the vicinity of
this appliance is hazardous.
FOR YOUR SAFETY
If you smell gas:
1. Don’t touch electrical switches.
2. Extinguish any open fl ames.
3. Immediately call your
gas supplier.
Model No.______________________________________________ Serial No. ________________________
INSTALLATION AND SERVICE MANUAL
PACKAGED ROOFTOP ARRANGEMENTS
FOR HEATING, COOLING AND VENTILATING SYSTEMS
ATTENTION: READ THIS MANUAL, RISM MANUAL, FACTORY INSTALLED OPTIONS MANUAL, UNIT SUBMITTAL DATA SHEETS
AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THESE
UNITS! CHECK UNIT DATA PLATES FOR TYPE OF GAS AND ELECTRICAL SPECIFICATIONS AND MAKE CERTAIN THAT THESE
AGREE WITH THOSE AT THE POINT OF INSTALLATION. RECORD THE UNIT MODEL NUMBER AND SERIAL NO.(S) IN THE SPACE
PROVIDED. RETAIN THIS DOCUMENT FOR FUTURE REFERENCE.
RBM-8
J30-05381
260 NORTH ELM ST., WESTFIELD, MA 01085
TEL: (413) 568-9571 FAX: (413) 562-8437
www.mestek.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - PACKAGED ROOFTOP ARRANGEMENTS

8/12RECEIVING INSTRUCTIONSInspect shipment immediately when received to determine if any damage has occurred to the unit during shipment. After the un

Strany 2 - TABLE OF CONTENTS

10When connecting supply air duct to Supply Plenum, attach duct to supply air opening fl ange when no dampers are used. Otherwise, if dampers are used,

Strany 3

11The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at

Strany 4

12Outdoor line voltage conduits leading into the unit should be installed to prevent rain from wetting any high voltage wire. Locate the thermostat in

Strany 5

13Figure 11 - Disconnect Box LocationsDX COIL EQUIPPED UNITS (OPTIONAL)See Coil Installation/Maintenance Manual for Refrigerant Piping, Liquid and Su

Strany 6 - III. INSTALLATION

14IV. OPERATIONGENERAL INFORMATION Refer to Outdoor Rooftop Gas-Fired Duct Furnace Installation and Service Manual for specifi c information regarding

Strany 7 - 12"

15Six Stage Units: Triple duct furnace models only. Each duct furnace is equipped with two stage heating but fi red independently giving six stages. E

Strany 8 - Figure 6

16Figure 13 - Belt Tension GuideThese units are set at the factory for the RPM required to meet the air volume (CFM) and external static pressure orde

Strany 9 - * Field Supplied

17Method to Check Manifold Pressure 1. Close the manual valve of unit gas valve. 2. Install a 1⁄8 inch pipe connection in the tapped hole provide

Strany 10

18Starting Unit in Heating Mode1. Close the unit disconnect switch which provides power to the unit. High voltage is present in some areas of the uni

Strany 11

19 4. Remove the locking screws holding the burnerdrawer assembly in position. 5. Slide the burner drawer out of the duct furnace. 6. Removal o

Strany 12 - 1. Mixed Air Controller

2TABLE OF CONTENTSI. RECEIVING Pre-Installation Instructions ... 2II. GENERAL REQUIREMENTS ...

Strany 13 - DRAIN PAN CONNECTION

20Figure 14STANDARD CFM BLOWERHIGH CFM BLOWERAAABFigure 15AABBAAKEY B PROJECTS TO PROVIDE A GRIP FOR REMOVING.DO NOT OPERATE SHEAVE WITH FLANGE PROJEC

Strany 14 - IV. OPERATION

21VII. TROUBLESHOOTINGFor troubleshooting of the duct furnace, refer to Outdoor Rooftop Gas-Fired Duct Furnace Installation and Service Manual. For E

Strany 15

22 PROBLEM PROBABLE CAUSE SOLUTION 1. Noise Blower Wheel a. Loose on shaft. b. Defective blower wheel. Do not run blow

Strany 16 - 1/2" TO 3/4"

23 PROBLEM PROBABLE CAUSE SOLUTION 2. CFM Low Filters Dirty or clogged. Insuffi cient Air Flow Coil - DX or Chilled Water

Strany 17 - V. START UP

24 PROBLEM PROBABLE CAUSE SOLUTION 3. Motor runs and then Partial loss of line voltage. Check for loose connections. dies d

Strany 18 - VI. MAINTENANCE

25 PROBLEM PROBABLE CAUSE SOLUTION 6. Belts mismatched Belts improperly tensioned, causing Replace belts and tension drive with

Strany 19

26TROUBLESHOOTING GUIDE – CHILLED WATER COOLING COIL PROBLEM PROBABLE CAUSE SOLUTION 1. No or Insuffi cient Cooling Circulating pum

Strany 20 - HIGH CFM BLOWER

27NOTE: ALL UNIT WEIGHTS ARE LESS MOTOR, OUTSIDE AIR HOOD AND COOLING COILS W/ DRAIN PAN FOR UNITS ORDERED WITH DOUBLE WALL CONSTRUCTION (OPTIONAL)

Strany 21 - VII. TROUBLESHOOTING

28 ROOF TOP ARRANGEMENT [RA] “M” ROOF TOP ARRANGEMENT [RA] “N” ROOF TOP ARRANGEMENT [RA] “P”Capacity [CA] NET WT. SHIP.WT. Capacity [CA] NET WT

Strany 22

29MOTOR SHIPPING WEIGHTS (APPROMIMATE)1 - (115/1/60) 2 - (208/1/60) 3 - (230/1/60)1ODP2TE3PEODP4PETE1ODP2TE3PEODP4PETE1ODP2TE3PEODP4PETE1/2 HP 20

Strany 23

3II. GENERAL SAFETY REQUIREMENTS Open all disconnect switches before installing the unit. Failure to do so may result in personal injury or death fro

Strany 24

30 ARRANGEMENTS “B” ARRANGEMENT “B” Unit Without Outside Air Hood With Outside Air Hood Type, Center of Gravity Corner Weights (lbs) Center of G

Strany 25

31 ARRANGEMENTS “G” ARRANGEMENT “G” Unit Without Outside Air Hood With Outside Air Hood Type, Center of Gravity Corner Weights (lbs) Center of G

Strany 26 - X. LIMITED WARRANTY

32 ARRANGEMENTS “K” with DX Cooling Coil ARRANGEMENT “K” with DX Cooling Coil Unit Without Outside Air Hood With Outside Air Hood Type, Center of

Strany 27

33XIII. UNIT NUMBER DESCRIPTIONDigit E X X — 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 +Item Prefi x UT CA FT FM RA CO GT GC SV MT MS AI AC AS

Strany 28

34ENGINEERED PRODUCTS ROOFTOP ARRANGEMENTS (RA)**Notes: 1. Arrangements are shown with the maximum number of furnaces available. 2. Optional air inl

Strany 29 - TE - Totally Enclosed

35XIV. GAS EQUIPMENT START-UPCustomer ____________________________________ Job Name & Number _________________________PRE-INSPECTION INFORMATIO

Strany 30 - XII. CENTER OF GRAVITY

260 NORTH ELM ST., WESTFIELD, MA 01085TEL: (413) 568-9571 FAX: (413) 562-8437www.mestek.com

Strany 31

4The venting is an integral part of the unit and must not be altered in the fi eld. The Natural Vented units are equipped with a ventcap which is desig

Strany 32

5LOCATIONBefore placing rooftop unit in its permanent location, make certain that the roof is capable of carrying the additional load of this equipme

Strany 33 - (Internal use Only)

6III. INSTALLATION Open all disconnect switches and secure in that position before installing unit. Failure to do so may result in personal injury or

Strany 34 - B/F/DEV SP

7Figure 5 - Roof Curb Kits Dimensional DataD38341-7/8" Typ.Flange12"W InsideB Outside1-1/2"FlangeF Inside1-7/8" Typ.Flange1-1/

Strany 35 - XIV. GAS EQUIPMENT START-UP

8Figure 7 - Unit/Curb End Rail AssemblyFigure 6D3809-3Unit/Base RailAssemblyCurb Cap End Adaptor -Supplied with the Unit(one each end).* For Field Ins

Strany 36

9Figure 8 - Roof Curb Specifi cations20-7/8"(530)20-7/8"(530)A*ReturnAirOpeningSupplyAirOpeningE*SectionY-YSectionX-XCapacity[ CA ]Dimension

Příbuzné modely PV | AH |

Komentáře k této Příručce

Žádné komentáře